Liquefied Petroleum Gas Certificate of Conformity
Do you need a Gas CoC? And does your gas installation comply to the standard?
An LPG CoC is necessary for your household insurance, sale of property and bond registration.
We will come out and inspect your installation and issue a CoC once the installation is up to standard as per SANS 10087-1:2024.
Areas serviced in Pretoria:
LPG COC Pretoria East , LPG COC Pretoria North , LPG COC Pretoria West , LPG COC Montana , LPG COC Faerie Glen , LPG COC Moreletta Park , LPG COC Centurion , LPG COC Olympus , LPG COC Garsfontein , LPG COC Meyers Park , LPG COC Murrayfield , LPG COC Silver Lakes , LPG COC Lombardy , LPG COC Shere , LPG COC Lynnwood , LPG COC Waterkloof , LPG COC Pierre Van Ryneveld , LPG COC Waverly , LPG COC Villeria , LPG COC Moregloed , LPG COC Bergtuin , LPG COC Queenswood , LPG COC Brooklyn , LPG COC Hatfield , LPG COC Arcadia , LPG COC Pretoria Gardens , LPG COC Booysens , LPG COC Midstream Estates , LPG COC Midstream Meadows , LPG COC Midstream Ridge , LPG COC Midfield , LPG COC Midstream Hill , LPG CO Midstream Heights , LPG COC Midlands , LPG COC Retire @ Midstream , LPG COC Amberfield Heights , LPG COC Amberfield Glen , LPG COC Amberfield Crest , LPG COC Amberfield Ridge , LPG COC Thatchfield Close , LPG COC Thatchfield Hills , LPG COC Thatchfield Crest
Areas serviced in Johannesburg
LPG COC Sandton , LPG COC Rosebank , LPG COC Melrose Arch , LPG COC Parkhurst , LPG COC Roodepoort , LPG COC Randburg , LPG COC Cresta , LPG COC Fourways , LPG COC Honeydew , LPG COC Lonehill , LPG COC Edenvale , LPG COC Linbro Park , LPG COC Bedfordview , LPG COC Glen Vista , LPG COC Meyersdal , LPG COC Alberton , LPG COC Brackenhurst , LPG COC Northcliff , LPG COC Northriding , LPG COC Krugersdorp , LPG COC Ruimsig , LPG COC Parkmore , LPG COC Sandhurst , LPG COC Birch Acres , LPG COC Atlasville , LPG COC Boksburg , LPG COC Rynfield , LPG COC Benoni , LPG COC Brakpan , LPG COC Braamfontein
Quick Contact
Do you already have an LPG Gas installation but you don’t know if its legal? Compare it to the following diagrams or give us a call to make sure.
Outside Installation
Containers shall be at least
Doors, Windows & Airbricks
1 m away from any opening (into a building) that is below the level of the container valve, ie. a) doors, windows and airbricks,b) 2 m away from any drain, pit or manhole,
3 m away from the property boundary wall, unless the boundary has a firewall, in which case the containers could be next to the firewall and where there are only two containers, the boundary distance can be reduced to 1 m, and,
3 m away from any opening (or window) directly above the containers. The 3 m distance from the top of the cylinder, valve connection or the manifold whichever is the higher, to the bottom of the window(s) may be reduced to a minimum of 300 mm providing that the cylinders are in a cage with a steel roof-top.
Roofs
4) a non-combustible roof (see SANS 10400) is installed between the containers and the The roof shall extend beyond the cylinder(s) such that when measured from the valve connection and around the roof to the nearest point of the window a minimum of 1,5 m safety distance shall be obtained, or
5) the window frames shall be steel and the total size of the glazing does not exceed 1 Glazing shall be of wire woven glass not larger than 450 mm × 450 mm per pane. Such windows shall not be openable.
6) where a roof is installed over the cylinders there shall be sufficient space above the cylinder valves to facilitate the exchange of Roof structures of concrete shall not be installed above the manifold or cylinder
Electrical Points
7) 5m away from a switchable electrical point i.e. plug socket, Inline power isolator, Aircon units, Pool pumps, Water pumps etc. Note, a wall light only needs to be 1.5m to the left/right of the bottles, or 1.5m above the bottles.
Read more about regulations